Technical specification

Transparent/Translucent Opaque
External skin Glass Glass
Internal skin Glass Gypsum board
Insulation core system 5 chambers (5 chamber core)
6 chambers (5 chamber core + single IGU)
7 chambers (5 chamber core + double IGU)
5 chambers
Element thickness (mm) 133 - 189 133 - 137
Modular width (mm) 700 - 1250 500 - 1250
Modular length (mm) 700 - 4000 300 - 4000
Weight (kg/m2) 75 - 130 43 - 67
U value – thermal transmittance (W/m2K)
[EN ISO 10211], across the whole modular unit
0.27 – 0.45
for the complete system at max. unit size
0.25
for the complete system at max. unit size
U value – thermal transmittance (W/m2K)
[EN 673:2011], center of glass value
0.19 (7 chambers) 0.17
g value – solar heat gain 0.1 – 0.25 /
LT - light transmittance (%) 15 - 35 /
Rw – sound insulation (dB)
[EN ISO 140-3]
45 - 60* 46 - 60*
Water permeability
(resistance to driving rain under pulsating pressure) [EN 12865]
900 - 1500 Pa 900 - 1500 Pa
Airtightness 0.1 m3/ m2/hr @50 Pa 0.1 m3/ m2/hr @50 Pa
Wind load resistance (kPa) 1.25 at L/400
at max. unit size
1.25 at L/400
at max. unit size
Fire resistance class
[EN 13501-2]
/ EI 60 - EI 120*
Recyclability (%) 96 96
STS-11/0023 National Technical Approval
* contact technical support

Dealers finder